Gas Pressure Conversion Tables: bar, mbar, PSI, kPa and inWC

1 bar = 1,000 mbar = 100 kPa = 14.504 PSI = about 401.5 inches of water column (in WC). To convert, multiply by the factor in the table below. The tables that follow cover the pressures that appear on LPG regulators, manifold safety valves and cryogenic relief valves, from 20 mbar up to 35 bar.
Conversion factors
| To convert from | to | multiply by |
|---|---|---|
| bar | mbar | 1,000 |
| bar | kPa | 100 |
| bar | PSI | 14.504 |
| PSI | bar | 0.06895 |
| PSI | mbar | 68.95 |
| PSI | kPa | 6.895 |
| mbar | in WC | 0.4015 |
| in WC | mbar | 2.491 |
Low pressures: mbar to bar, PSI, in WC and kPa
Low-pressure (second stage) regulators for appliances work in this range. For example, several regulators in our range have a 37 mbar outlet.
| mbar | bar | PSI | in WC | kPa |
|---|---|---|---|---|
| 20 | 0.020 | 0.29 | 8.0 | 2.0 |
| 28 | 0.028 | 0.41 | 11.2 | 2.8 |
| 37 | 0.037 | 0.54 | 14.9 | 3.7 |
| 50 | 0.050 | 0.73 | 20.1 | 5.0 |
| 70 | 0.070 | 1.02 | 28.1 | 7.0 |
| 100 | 0.100 | 1.45 | 40.1 | 10.0 |
| 200 | 0.200 | 2.90 | 80.3 | 20.0 |
| 350 | 0.350 | 5.08 | 140.5 | 35.0 |
| 690 | 0.690 | 10.01 | 277.0 | 69.0 |
Intermediate and high pressures: bar to mbar, PSI and kPa
| bar | mbar | PSI | kPa |
|---|---|---|---|
| 1 | 1,000 | 14.5 | 100 |
| 1.5 | 1,500 | 21.8 | 150 |
| 2 | 2,000 | 29.0 | 200 |
| 2.8 | 2,800 | 40.6 | 280 |
| 3.1 | 3,100 | 45.0 | 310 |
| 3.5 | 3,500 | 50.8 | 350 |
| 7 | 7,000 | 101.5 | 700 |
| 8.6 | 8,600 | 124.7 | 860 |
| 18 | 18,000 | 261.1 | 1,800 |
| 24.1 | 24,100 | 349.5 | 2,410 |
| 31 | 31,000 | 449.6 | 3,100 |
| 35.2 | 35,200 | 510.5 | 3,520 |
PSI to mbar, bar and kPa
| PSI | mbar | bar | kPa |
|---|---|---|---|
| 2 | 138 | 0.14 | 13.8 |
| 10 | 689 | 0.69 | 68.9 |
| 15 | 1,034 | 1.03 | 103.4 |
| 20 | 1,379 | 1.38 | 137.9 |
| 30 | 2,068 | 2.07 | 206.8 |
| 45 | 3,103 | 3.10 | 310.3 |
| 50 | 3,447 | 3.45 | 344.7 |
| 100 | 6,895 | 6.89 | 689.5 |
| 250 | 17,237 | 17.24 | 1,723.7 |
| 350 | 24,132 | 24.13 | 2,413.2 |
| 450 | 31,026 | 31.03 | 3,102.6 |
| 510 | 35,163 | 35.16 | 3,516.3 |
Where these pressures appear in our range
- 37 mbar: low-pressure LPG regulators, such as the GB 4 kg/hr regulator and the Novacomet 70 kg/hr regulator.
- 0.07–1.03 bar (1–15 PSIG) up to 2.76–6.89 bar (40–100 PSIG): the RegO 597F series high-pressure regulators. See the 597F comparison.
- 18 bar (about 261 PSI): the manifold safety valve.
- 24.1, 31.0 and 35.2 bar (350, 450 and 510 PSIG): RegO cryogenic relief valves such as the PRV9434T350.
Gauge pressure and absolute pressure
Most regulator and relief valve ratings are gauge pressure: the pressure above the surrounding atmosphere, written PSIG or barg. Absolute pressure (PSIA or bara) adds the atmosphere, about 1.013 bar or 14.7 PSI at sea level. A 10 PSIG regulator setting is about 24.7 PSIA. If a data sheet does not say which it uses, ask.
Frequently asked questions
How many inches of water column is 37 mbar?
About 14.9 in WC.
What is 2 PSI in mbar?
About 138 mbar.
Is 1 bar the same as 1 atmosphere?
Nearly. 1 standard atmosphere is 1.01325 bar.
Regulators
Browse first stage regulators, second stage regulators and OPSO/UPSO regulators. Request a quote.
Conversion conventions and pressure reference
Water-column conversions depend on the reference convention and temperature. The rounded values above follow the approximately 249.09 Pa per inch-of-water convention shown in the NIST conversion reference. State the convention when higher precision matters.
A unit conversion changes the unit, not the pressure reference. For example, converting 2 PSIG to about 138 mbar gives gauge pressure; it does not give absolute pressure. To obtain absolute pressure, use the actual local atmospheric pressure. The standard-atmosphere value is an approximation for an example, not the local pressure at every site.
Related guides
- Are Pressure Gauges Good? Accurate, Reliable, and Essential for Gas Systems
- First Stage Regulators: The Key to Safe, Efficient LPG Systems
Equipment and enquiries
Request a gas-equipment quotation with the application, model reference where known, operating requirements, quantity and delivery location.
Sources and further technical reading
General equipment-selection information. Confirm the exact model documentation and applicable project requirements with qualified personnel before selection, installation or adjustment.